J2-5104/5105 Pan/Tilt/Camera Right and Left Side SLV Sensor

| Size: |
|
9.1” (W) x 10.4” (H) x 6.9” (D) |
| Weight: |
|
13.3 lb |
| Housing Construction: |
|
6061 T6 Aluminum, Anodized per MIL-A-8625F, Type III |
| Housing Mating Surfaces: |
|
MIL-DTL-5541F, Class 3, (non-Hexavalent) coated |
| Top Coat: |
|
Per MIL-DTL-53039, 686A Tan |
| Electrical Connection: |
|
MIL-DTL-38999 Series III |
| Power Receptacle: |
|
D38999/24WC98PN |
| Comm/Video/Program Receptacle: |
|
D38999/24WB35PN |
| Pan/Tilt Drive Train: |
|
17-4 PH Stainless Steel spur gear pair driven by high precision stepper motor / gear head / gear head assembly. |
| Rotary Axis Sealing: |
|
Dual spring energized rotary lip seals provided redundant particulate and moisture ingress protection and wear compensation. |
| Camera Housing: |
|
Equipped with exterior truncated cooling fins for improved passive cooling capacity. |
| Proprietary shock/vibration protected EO and IR camera assemblies |
|
|
| Chassis Ground: |
|
Provided by the Pan/tilt base, J1 (D38999/24WC98PN), and J2 (D38999/24WB35PN) receptacle connector housings |
| Max continuous: |
|
1.5 Amps @ 24VDC |
| In rush: |
|
13.3 Amps @ 24VDC, 100 us. |
| Heater: |
|
3.75 Amps @ 24VDC |
| Reverse Polarity Protection: |
|
Yes |
| MIL-STD-1275D: |
|
Compliant |
| Pan/Tilt Assembly: |
|
80,000 hours |
| EO camera module: |
|
59,000 hours |
| IR camera module: |
|
44,000 hours |
| Pan Movement: |
|
360° continuous |
| Pan Speed: |
|
0.1°/sec to 70°/sec |
| Pan Accuracy: |
|
.1 degree |
| Pan Repeatability: |
|
.1 degree |
| Tilt Movement: |
|
+90° to -45° (135° included tilt angle) |
| Tilt Speed: |
|
0.1°/sec to 25°/sec |
| Tilt Accuracy: |
|
.1 degree |
| Tilt Repeatability: |
|
.1 degree |
Bit Supported
|
|
Camera Specifications
|
|
The J2-5104 camera head consists of two camera assemblies; one color (EO) zoom camera assembly and one IR fixed camera assembly. Video outputs are transmitted simultaneously. |
| Signal Format: |
|
NTSC |
| Image Sensor: |
|
1/4” type EXview HAD CCD |
| Number of Effective Pixels: |
|
Approximately 380,000 pixels |
| Horizontal Resolution: |
|
550 TV Lines (Wide end) |
| Lens: |
|
36x Zoom, f=3.4mm (wide) to 122.4 mm (tele), F1.6 to F4.5 |
| Digital Zoom: |
|
12x (432x with optical zoom) |
| Angle of View (H): |
|
57.8 degree (wide end) to 1.7 degree (tele end) |
| Min. Working Distance: |
|
320mm (wide end) to 1500mm (tele end) |
| Sync. System: |
|
Internal/External (V-Lock) |
| Min Illumination (F1.6, 50IRE): |
|
1.4 lux 1/60 sec, 0.1 lux 1/4 sec
ICR-ON Mode 0.01 lux 1/4 sec |
| Recommended Illumination: |
|
100 to 100,000 lux |
| S/N Ratio: |
|
50dB |
| Back Light Compensation: |
|
ON/OFF |
| Electronic Shutter: |
|
1/4 to 1/10,000 Sec 20 steps |
| White Balance: |
|
Auto |
| Gain: |
|
Auto/manual (-3 to 28dB) |
| Aperture Control: |
|
16 steps |
| Preset: |
|
6-Positions |
| Video Output: |
|
VBS 1.0Vp-p 75 ohm |
| Signal Format: |
|
RS-170 |
| Focal Plane Array: |
|
ASi Microbolometer |
| Spectral Range: |
|
7.5- 13.5µm |
| Number of Pixels: |
|
640(H) x 480(V) |
| Pixel Size: |
|
17µm |
| Scan Mode: |
|
Progressive |
| Frame Rate: |
|
30 Hz max |
| NETD: |
|
< 50° mK @ 300K, f/1.0 |
| Scene Temperature Range (saturation): |
|
+ 80ºC from camera temperature |
| Start Up Time: |
|
<3 seconds at room temperature |
| Max. Operational Temperature: |
|
+75ºC |
| Storage Temperature: |
|
-45ºC to +100ºC |
| Lens: |
|
40°HFOV fixed focus lens (22mm), athermal, F1.2 |
The J2-5104 has passed the following environmental tests:
| Lightweight Shock: |
|
MIL-S-901D, Grade A, Type A, Class 1 |
The J2-5104 has met the following environmental requirements by extension through commonality to the Vision Technologies J2 camera family:
EMI:
| Conducted Emissions, Power Leads: |
|
MIL-STD-461E CE102 (10kHz-100MHz) |
| Conducted Susceptibility, Power Leads: |
|
MIL-STD-461E CS101 ((30Hz-150kHz) |
| Conducted Susceptibility, Bulk Cable Injection: |
|
MIL-STD-461E, CS114 (10kHz-200MHz) |
| Conducted Susceptibility, Impulse Excitation: |
|
MIL-STD-461E CS115 |
| Conducted Susceptibility, Damped Transients: |
|
MIL-STD-461E CS116 (10kHz-100MHz) |
| Radiated Emissions, Magnetic Field: |
|
MIL-STD-461E RE101 (30Hz-100kHz) |
| Radiated Emissions, Electric Field: |
|
MIL-STD-461E RE102 (2MHz-18GHz) |
| Radiated Susceptibility, Magnetic Field: |
|
MIL-STD-461E RS101 (30Hz-100kHz) |
| Radiated Susceptibility, Electric Field: |
|
MIL-STD-461E RS103 (2MHz-18GHz) |
| DC Magnetic Field: |
|
MIL-STD-1399 Section 070 |
Natural Environmental:
| Vibration: |
|
MIL-STD-167-1, Type 1 |
| Elevation: |
|
MIL-STD-810F, Method 500.4 Procedure I (to 4,000 feet) |
| High Temperature: |
|
MIL-STD-810F, Method 501.4, Pro. I & II (high temperature 50ºC) |
| Low Temperature: |
|
MIL-STD-810F, Method 502.4, Pro. I & II (low temperature) |
| Temperature Shock: |
|
MIL-STD-810F, Method 503.4, Pro. I (-40ºC to +70ºC) |
| Blowing Rain: |
|
MIL-STD-810F, Method 506.4, Pro. I |
| Humidity: |
|
MIL-STD-810F, Method 507.4 |
| Fungus: |
|
MIL-STD-810F, Method 508.5 (28 days) |
| Salt Fog: |
|
MIL-STD-810F, Method 509.4 |
| Blowing Dust: |
|
MIL-STD-810F, Method 510.4, Pro. I |
| Blowing Sand: |
|
MIL-STD-810F, Method 510.4, Pro. II |
| Settling Dust: |
|
MIL-STD-810F, Method 510.4, Pro. III |
| Explosive Atmosphere: |
|
MIL-STD-810F, Method 511.4, Pro. I |
| Noise Level: |
|
MIL-STD-740-1, -2, MIL-STD-1474 |
| Inclination-Operation: |
|
DOD-STD-1399 Section 301 (+/- 45º, 5-7 cpm) |
In addition, The J2-5104 is designed to meet the following environmental requirements or has met them through extension of the tests performed above:
| Elevation: |
|
MIL-STD-810F, Method 500.4 Procedure I (to 50,000 feet) |
| High Temperature: |
|
MIL-STD-810F, Method 501.4, Pro. I & II (high temperature +60ºC) |
| Temperature Shock: |
|
MIL-STD-810F, Method 503.4, Pro. I (-50ºC to +71ºC) |
| Immersion: |
|
MIL-STD-810F, Method 512.4, Pro. I |
| Acceleration: |
|
MIL-STD-810F, Method 513.5, Pro. I, II, III |
| Shock: |
|
MIL-STD-810F, Method 516.5, Pro IV |
| Bench Handling Shock: |
|
MIL-STD-810F, Method 516.5, Pro. I, IV, VI |
| Vibration: |
|
MIL-STD-810F, Method 514.5, Pro. I, II (Category 20) |
| Contamination by Fluids: |
|
MIL-STD-810F, Method 504 |
| Icing and Freezing Rain: |
|
MIL-STD-810F, Method 521.2 |
| Wind loading: |
|
28.3 m/s sustained wind velocity, 43.6m/s wind gusts |
| Inclination/tilt: |
|
+/- 180° inclination, 31° tilt all directions |
Vision Technologies proudly offers 901-D “Grade A”
Shock Certified Camera Systems 
Featured Product
J2-3003 Vehicle Mounted Imaging System
The J2 EFV System consists of two pan and tilts and one fixed EO/IR camera designed specifically to provide the vehicle driver, car commander and tro...
News & Events